The Perlick GB1-6 Glycol Bath 140 Gph Recirculating Pump with (6) Flash Chill Lines is a commercial-grade glycol circulation system designed for precise temperature control in foodservice environments. Engineered by Perlick Corporation, this model features a robust 140 gallons per hour recirculating pump and six flash chill lines, facilitating efficient and uniform chilling. The system is ideal for applications requiring consistent cooling and rapid temperature adjustments, such as beverage lines and food processing operations. Its durable construction and high-performance pump optimize workflow integration, ensuring reliable operation in demanding commercial kitchens and bar stations.
Top Perlick GB1-6 Features
The Perlick GB1-6 Glycol Bath pump offers targeted glycol recirculation for optimal temperature management, integrating seamlessly into existing refrigeration or beverage chill lines. Its stainless steel components ensure long-term durability in high-use environments, while straightforward maintenance enhances operational uptime. The system's precise flow rate supports consistent cooling in factory or bar setups, improving workflow efficiency. Designed for moderate volumes, it suits medium-demand foodservice and beverage operations, providing reliable heat exchange for multiple chill lines.
- High-capacity pump: 140 GPH flow supports multiple chill lines
- Corrosion-resistant construction: Stainless steel pump body and fittings enhance longevity
- Easy maintenance: Simple disassembly for routine cleaning and parts replacement
- Multiple chill line integration: Supports (6) flash chill lines for distributed cooling
- Robust design for demanding environments: Suitable for commercial kitchen and bar facilities
Designed for foodservice operators seeking reliable glycol recirculation to maintain consistent chilled product flow.
Perlick GB1-6 Technical Specs
The Perlick GB1-6 Glycol Bath pump operates on a standard commercial electrical setup, typically requiring a 120V, 60Hz power supply operating in a single-phase configuration with a rated amperage of approximately 10A and wattage around 1200W. It employs air-cooled technology to dissipate heat efficiently, suitable for installation in environments with adequate airflow. Crafted from stainless steel, the pump withstands continuous operation and cleaning processes, while its compact dimensions—approximately 24 inches wide, 12 inches deep, and 10 inches high—allow flexible integration into existing systems. It has been tested for reliable operation within a temperature range of 36°F to 85°F, ensuring compatibility with food industry sanitation standards and cleaning protocols. The unit’s weight is approximately 40 pounds, reflecting its durable metal construction, and its versatile setup supports multiple refrigerant lines with a 6-line configuration for distributed chilling applications.
- Electrical requirements: 120V, 60Hz, single-phase, approximately 10A, 1200W
- Cooling method: Air-cooled system for heat dissipation
- Production capacity: 140 GPH circulating pump flow rate
- Construction & finish: Stainless steel body for corrosion and wear resistance
- Dimensions & weight: 24" W x 12" D x 10" H; approximately 40 lbs
- Temperature resistance: Operates within 36°F to 85°F ambient temperature
- Food safety & cleaning: Food-safe materials with easy disassembly for cleaning
Usage considerations include:
- Electrical compatibility: Ensure dedicated 120V outlet with proper grounding
- Plumbing connection: Compatible with standard glycol lines and fittings
- Airflow clearance: Install with adequate ventilation for optimal cooling
- Drainage setup: Proper drainage for condensate and maintenance access
- Maintenance routine: Periodic cleaning of pump components and inspection
What is a commercial glycol bath pump
A commercial glycol bath pump is a specialized recirculating system used for temperature regulation in foodservice environments. It continuously circulates glycol through chill lines to maintain consistent cooling of beverage and food products. The Perlick GB1-6 Glycol Bath, with its 140 GPH capacity and six flash chill lines, is installed in setups such as bar beverage lines or food processing stations. Designed for durability and performance, it supports medium-volume operations and ensures uniform temperature control, making it suitable for various commercial kitchens and beverage service applications.
Top Glycol Bath Systems for Foodservice Environments
Reliable and robust, the Perlick GB1-6 Glycol Bath supports medium-demand cooling workflows in commercial kitchens, with precise temperature control and multiple chill line integration. Built by Perlick Corporation, this unit is ideal for beverage and food processing settings needing consistent glycol circulation for operational efficiency and product quality.
- Operation Type — suitable for moderate-volume foodservice workflows
- Kitchen Setting — ideal for bar, beverage, and preparation areas
- Foodservice Category — designed for glycol circulation in restaurants and cafes
- Workload Qualifier — supports medium throughput applications
- Use Case — primary for temperature regulation of chilled products and lines
Why Choose Perlick GB1-6 Glycol Bath System
Opting for the Perlick GB1-6 provides a reliable, durable solution with a high-capacity pump and multiple flash chill line support. Its corrosion-resistant, stainless steel construction ensures longevity in demanding environments, while easy maintenance reduces downtime. This system’s compact design integrates seamlessly into existing glycol setups, enhancing operational efficiency compared to less specialized or lower-capacity alternatives.
- Self-contained design simplifies installation and reduces system complexity
- Supports multiple glycol chill lines for distributed cooling
- Constructed from high-grade stainless steel for durability
- Optimized for medium-volume commercial foodservice operations
- Enhanced workflow integration with reliable recirculation performance