The Russell -ACP1 Valve Expansion Auto Acp 1 by AllPoints is a professional refrigeration component designed for precise control and reliable performance in commercial HVAC and refrigeration systems. This auto expansion valve features a maximum working temperature of 300°F, making it suitable for high-temperature environments involving refrigerants such as R-12, R-22, R-134a, R-401a, R-402a, R-404a, R-407a, R-407b, R-502, and R-507. It includes a 1/4" SAE inlet and an adjustable outlet ranging from 3/8" to 1/2" SAE, with a maximum operating pressure of 500 PSI, ensuring compatibility and effective regulation within various refrigeration circuits. Engineered for technicians and specialists in commercial refrigeration, this safeguard component allows precise refrigerant flow management, optimizing system efficiency and stability across diverse foodservice and industrial cooling applications.
Top AllPoints -ACP1 Features
The AllPoints -ACP1 Valve Expansion Auto Acp 1 delivers accurate refrigerant metering, robust construction from durable materials, and ease of installation. Its adjustable outlet facilitates tailored system integration, while the high-pressure capacity supports demanding refrigeration environments. Designed for maintenance simplicity, it ensures long-term reliability in commercial foodservice cooling systems. Suitable for installations requiring precise temperature regulation and refrigerant flow control, this component enhances workflow efficiency for HVAC technicians and refrigeration engineers.
- Functionality: Provides precise refrigerant expansion control in cooling systems
- Durability: Constructed from high-quality materials rated for 500 PSI
- Ease of Use: Features adjustable outlet for flexible system fitment
- Real-world Application: Ideal for commercial refrigeration setups involving R-134a and other refrigerants
- Workflow Benefit: Ensures consistent temperature regulation with minimal maintenance
Recommended for refrigeration system optimization and refrigerant flow regulation in commercial foodservice facilities.
-ACP1 Technical Specs
The -ACP1 auto expansion valve from Russell is engineered for commercial refrigeration with an operating temperature range up to 300°F. It features a 1/4" SAE inlet and an adjustable outlet from 3/8" to 1/2" SAE, supporting a maximum working pressure of 500 PSI. Manufactured in Mexico, this model weighs 1.65 pounds and measures 3.5 inches in height, width, and 5 inches in depth. Its robust construction ensures reliable operation under demanding conditions typical of industrial and foodservice refrigeration environments. The valve’s design facilitates easy installation and maintenance, making it suitable for systems utilizing R-12, R-22, R-134a, and similar refrigerants, contributing to system stability and thermal performance.
- Refrigerant Compatibility: Suitable for R-12 R-22 R-134a R-401a R-402a R-404a R-407a R-407b R-502 R-507
- Maximum Working Pressure: 500 pounds per square inch
- Material Construction: Durable materials rated for high-pressure environments
- Dimensions: 3.5" W x 5" D x 3.5" H
- Weight: 1.65 lbs
- Temperature Range: Up to 300°F maximum working temperature
- Electrical Requirements: Not applicable (manual control device)
- Cooling Method: Not applicable (passive fluid control)
- Refrigeration Type: Compatible with self-contained or remote systems
- Installation Clearance: Minimum 2 inches for inlet/outlet connections
- Maintenance Access: Easy disassembly for inspection and servicing
- Mounting Options: Designed for standard industrial piping connections
- Material Safety: Suitable for use with food-grade refrigerants and cleaning protocols
What is a commercial auto expansion valve
A commercial auto expansion valve is a precision device used in refrigeration and air conditioning systems to regulate refrigerant flow and maintain stable evaporator pressure. The Russell -ACP1 Valve Expansion Auto Acp 1 is designed for industrial and foodservice applications, installed in systems handling R-12, R-22, R-134a, among others. This model features a maximum working temperature of 300°F, a 1/4" SAE inlet, and an adjustable outlet from 3/8" to 1/2". Suitable for systems requiring reliable refrigerant regulation, it enhances system performance and energy efficiency in mid-sized commercial refrigeration units for food storage, beverage cooling, or cold storage warehouses.
Top commercial auto expansion valves for R-134a foodservice settings
Designed for medium-volume refrigeration workflows, the -ACP1 from AllPoints by Russell ensures precise refrigerant flow regulation, suitable for commercial kitchen cooling, hospital cold storage, and food processing plants. Its robust construction and adjustable features support reliable operation during routine maintenance and system servicing, making it an integral component for efficient refrigeration system management.
- Operation Type — suitable for medium-duty commercial refrigeration
- Kitchen Type — ideal for compact or self-contained foodservice facilities
- Foodservice Category — supports cooling, freezing, and storage applications
- Workload Qualifier — handles moderate thermal loads effectively
- Use Case — enhances refrigerant flow stability in commercial refrigeration systems
Why Choose AllPoints -ACP1?
Why Choose the AllPoints -ACP1 Valve Expansion Auto Acp 1? This model offers a durable, high-pressure rated component with adjustable outlets designed for precise refrigerant control, improving system efficiency and reliability. Its construction from quality materials, coupled with flexible installation features, makes it superior to standard models, ensuring consistent performance in demanding foodservice refrigeration environments.
- Compact footprint designed for space-constrained setups
- Rugged materials supporting high-pressure operation
- Adjustable outlets for system customization
- Reliable regulator compatible with multiple refrigerants
- Easy maintenance with disassembly features for routine inspection