The Gaylord Industries 12826 Break Glass Station 440 Volt is a commercial safety device designed for emergency shutdown and manual alert activation in industrial and food processing environments. Built by Gaylord Industries, this OEM-grade break glass station operates on a 440-volt power supply, featuring a durable, impact-resistant glass faceplate that ensures reliable activation during critical situations. Its robust construction incorporates high-quality materials suitable for demanding 440V electrical systems, providing safety compliance and consistent performance. This safety station is integral to industrial and commercial foodservice facilities, offering a reliable solution for emergency activation and process control in high-voltage environments.
Top Gaylord Industries 12826 Features
Designed for commercial foodservice facilities requiring high-voltage safety measures, the Gaylord Industries 12826 break glass station provides rapid emergency shutdown. Its impact-resistant glass faceplate and corrosion-resistant housing ensure longevity in busy kitchens and processing plants. The station’s compact design facilitates easy mounting and integration into existing electrical safety systems, enabling quick response during emergencies. It combines durability with straightforward maintenance, supporting operational safety protocols in industrial kitchen environments and HACCP-compliant setups.
- Impact-resistant glass faceplate: Ensures durability for high-traffic commercial settings.
- Corrosion-resistant metal housing: Suitable for wet and humid industrial kitchens.
- Easy mounting design: Simplifies installation in existing safety stations or control panels.
- High-voltage compatibility: Operates reliably with 440V electrical systems for industrial safety.
- Low-maintenance construction: Facilitates quick inspections and minimal downtime during routine checks.
Designed for safety managers and industrial kitchen operators implementing emergency shutdown protocols.
Gaylord Industries 12826 Technical Specs
The Gaylord Industries 12826 break glass station operates on a 440 Volt electrical system with a frequency of 60 Hz, providing reliable emergency activation with a power consumption of 0.5 Amps. Its impact-resistant face is built from tempered glass, mounted on a corrosion-resistant stainless steel housing measuring 11 inches wide, 16 inches deep, and 10 inches tall. The unit weighs approximately 6.7 lbs and features a robust construction suitable for industrial environments. The station is designed for easy wall mounting with standard electrical connections, ensuring compliance with safety standards for high-voltage emergency control devices. Maintenance involves routine inspection of the glass face and mounting hardware, with minimal disassembly required for replacement.
- Electrical Requirements: 440V, 60Hz, 0.5A, 2200W
- Construction & Finish: Stainless steel housing with tempered glass faceplate
- Dimensions: 11 in W x 16 in D x 10 in H
- Weight: 6.7 lbs
- Temperature Resistance: Operating range 0°F to 130°F
- Mounting & Compatibility: Wall-mounted, suitable for industrial safety panels
Electrical connection: Requires 440V power supply with secure wiring integration
Installation clearance: 2 inches of clearance recommended for maintenance access
Environmental requirements: Suitable for humid environments with corrosion-resistant housing
Maintenance routine: Visual inspection of glass and mounting hardware every 6 months
Safety features: Impact-resistant glass, tamper-proof installation points
What is a commercial break glass station?
A commercial break glass station is a safety device used in industrial and foodservice settings for emergency shutdown or alert activation. It typically consists of a sturdy, impact-resistant glass faceplate that, when broken, completes an electrical circuit to trigger alarms, shut down machinery, or activate safety protocols. The Gaylord Industries 12826 is a high-voltage rated model designed for 440-volt systems, installed in strategic locations within processing and industrial kitchens to ensure fast response during critical incidents. It is ideal for use in high-voltage environments requiring rapid emergency activation and reliable operation under demanding conditions.
Top 440V Safety Devices for Industrial Foodservice Operations
Industrial high-voltage safety devices like the Gaylord Industries 12826 ensure rapid emergency shutdown in demanding commercial foodservice and processing environments. Built for longevity and reliable performance during high-workload scenarios, it is suitable for high-voltage safety protocols in HACCP-compliant facilities. This model from AllPoints Other, identifiable by model number 12826, is ideal for critical control stations and safety zones in industrial kitchens with moderate throughput needs.
- Operation in high-voltage environments — ensures safety in heavy-duty kitchens
- Industrial-grade materials — stainless steel and tempered glass for durability
- Designed for moderate workload safety applications — reliable in busy food-processing facilities
- Ease of maintenance — impact-resistant faceplate simplifies safety checks
- Seamless integration — wall-mounting with standard electrical wiring
Why Choose Gaylord Industries 12826 Break Glass Station
Gaylord Industries 12826 stands out from similar safety stations due to its high-voltage capability, robust construction, and ease of installation. Its impact-resistant tempered glass and corrosion-resistant housing provide long-term durability in industrial kitchens and processing plants. Designed for 440V systems, it enhances safety protocols and emergency response efficiency, making it a reliable choice for high-voltage safety control in demanding environments.
- High-voltage rated: Operates safely at 440V systems for industrial applications
- Robust construction: Impact-resistant glass and corrosion-proof housing extend lifespan
- Compact design: Fits seamlessly into existing safety infrastructure
- Premium materials: Stainless steel and tempered glass for longevity and safety
- Easy maintenance: Minimal disassembly required for routine inspections and glass replacement