The Parker Hannifin 084S Filter Drier Liquid Line from AllPoints is a professional-grade refrigerant filtration device designed for optimal performance in commercial refrigeration systems. Crafted with durable materials, this OEM model features a 1/2" Odf Solder connection, ensuring secure integration within liquid lines. Compatible with all widely used refrigerants, it effectively removes moisture and contaminants, extending component lifespan and maintaining system efficiency. Its precise technical specifications include a compact 3-inch height, 3-inch width, 7-inch depth, and a weight of 1.15 lbs, making it suitable for a variety of commercial refrigeration applications. This filter drier excels in isolating impurities to prevent system clogs and corrosion, ensuring reliable operation in demanding environments.
Top AllPoints 084S Features
The Parker Hannifin 084S liquid line filter drier offers robust moisture removal, high compatibility across refrigeration types, and ease of installation in commercial systems. Engineered for durability with corrosion-resistant braze joints, it simplifies maintenance and enhances workflow continuity. Its 1/2" solder connection ensures precise fitment for liquid lines, making it ideal for mid-volume cooling applications in retail and foodservice facilities.
- Moisture and contaminant removal: Prevents system corrosion and clogs
- Durable construction with brass fittings: Ensures long-term reliability
- Easy solder connection installation: Facilitates quick setup and servicing
- Optimized for refrigerant compatibility: Suitable with all common commercial refrigerants
- Compact 3-inch height and lightweight design: Supports space-efficient installation
Ideal for professional refrigeration setups requiring efficient filtration and system protection in commercial environments.
Parker Hannifin 084S Technical Specs
The Parker Hannifin 084S filter drier features a compact design suitable for demanding commercial refrigeration systems, with dimensions of 3 inches in height, 3 inches in width, and 7 inches in depth. Constructed primarily from corrosion-resistant materials and finished in a durable metallic tone, it weighs approximately 1.15 lbs. It is designed for use with all common refrigerants, supporting a seamless integration into liquid lines via a 1/2" Odf solder inlet. Its operating temperature range accommodates typical refrigeration environments, ensuring reliable moisture and debris filtration. The device requires no electrical power and is straightforward to install with standard soldering tools, offering minimal maintenance needs and facilitating quick replacements if necessary. Its resistance to corrosion and robust construction make it suitable for long-term operation in various foodservice and commercial cooling systems.
- Electrical Requirements: No electrical connection required
- Dimensions: 3" W x 3" H x 7" D
- Weight: 1.15 lbs
- Construction & Finish: Metal with corrosion-resistant properties
- Operating Range: Suitable for typical refrigeration temperatures
- Compatibility: Compatible with all standard refrigerants
What is a commercial liquid line filter drier
A commercial liquid line filter drier is a vital component within refrigeration and air conditioning systems that removes moisture and particulates from refrigerant flows. Typically installed in the liquid line, it helps prevent corrosion, sludge buildup, and system failures. The Parker Hannifin 084S model is specifically designed for stable, reliable filtration with a solder connection for seamless integration into commercial refrigeration setups, including retail stores, cold storage, and foodservice operations. Its robust construction and compatibility ensure optimal system performance, making it an essential part of maintaining the longevity and efficiency of medium-scale cooling systems used in various foodservice and commercial environments.
Top commercial refrigerant filtration for foodservice environments
Designed for medium-pressure refrigeration systems, the Parker Hannifin 084S from AllPoints offers precise filtration and easy installation, supporting best practices in commercial foodservice refrigeration. Manufactured with high durability and compatibility in mind, it is well-suited for foodservice facilities requiring dependable filtration solutions to maintain system integrity during operation. Ideal for medium-volume cooling workflows, it ensures contaminant control in retail refrigeration, cold storage, and similar foodservice settings.
- Operation Type — suitable for medium-volume commercial refrigeration systems
- Kitchen Setting — ideal for retail and foodservice facilities
- Foodservice Category — supports walk-in coolers and refrigerated display cases
- Workload Qualifier — designed for moderate throughput environments
- Use Case — effective in preventing moisture-related system failures
Why Choose AllPoints 084S?
The AllPoints 084S filter drier stands out from competitors with its durable construction, universal refrigerant compatibility, and streamlined solder connections that facilitate quick installation. Its robust design enhances system reliability while minimizing maintenance downtime, making it preferred for professional refrigeration systems. Built for long-term performance, it ensures consistent moisture removal and contaminant filtration, supporting operational efficiency and system health in commercial foodservice operations.
- Self-contained design: Simplifies installation and reduces system complexity
- Corrosion-resistant materials: Ensures longevity in harsh environments
- Compact footprint: Fits easily into space-constrained refrigeration lines
- Universal refrigerant compatibility: Supports all common refrigerants for versatility
- Cabinet-ready installation: Supports quick, secure solder connections