The Parker Hannifin 033116-01 Filter Drier Liquid Line is a professional-grade refrigeration component designed for commercial HVAC systems. This liquid line filter drier features a durable gold label construction with a 1/4" SAE male flare connection on one end and a female flare on the other, model 032mf. Compatible with all widely used refrigerants, it effectively eliminates moisture and contaminants to ensure optimal system performance. Its precise technical specifications include a height of 2 inches, width of 2 inches, and depth of 5 inches, with a weight of 0.4 lbs, making it suitable for demanding commercial refrigeration and air conditioning applications. Built to meet rigorous industry standards, this OEM product supports maintaining system integrity and reducing downtime in critical refrigeration setups.
Top Parker Hannifin 033116-01 Features
Designed for commercial refrigeration workflows, the Parker Hannifin 033116-01 filter drier offers precise moisture removal and contaminant filtration with its high-capacity filtration matrix. Its robust construction ensures resistance to corrosion and mechanical stress, enabling long-term reliability in demanding environments. The compact design simplifies installation and maintenance, while compatibility with all common refrigerants ensures versatility across various HVAC systems. Its sealed flare fittings facilitate secure connections, reducing leak risks and optimizing workflow integration in complex refrigeration setups. The filter drier's high-quality materials support easy cleaning and replacement, ensuring system cleanliness and operational efficiency for mid-volume foodservice and maintenance operations.
- Filtration Capacity: Eliminates moisture and particulates to protect system components
- Material Durability: Constructed from corrosion-resistant metals for long-term use
- Ease of Maintenance: Snap-fit flare connections facilitate quick installation and replacement
- Application Fit: Compatible with all popular refrigerants for versatile system use
- Workflow Optimization: Compact size supports seamless integration into existing refrigeration lines
Ideal for commercial HVAC technicians installing or servicing refrigeration systems requiring reliable moisture control.
033116-01 Technical Specs
The Parker Hannifin 033116-01 filter drier incorporates a rugged aluminum construction with a standard height of 2 inches, width of 2 inches, and depth of 5 inches. It weighs approximately 0.4 lbs, providing a lightweight yet durable component suitable for demanding commercial environments. This OEM model is designed for use with all common refrigerants, supporting system compatibility and ease of integration. The product is manufactured in the United States with a focus on high-performance filtration and moisture removal. Its sealed flare fittings ensure secure connections, reducing refrigerant leaks and enhancing system reliability. Operating within a temperature range suitable for typical refrigeration applications, it provides long-lasting performance that supports maintenance routines and system efficiency.
- Electrical Requirements: Not applicable, designed for refrigeration line connections
- Connection Type: 1/4" SAE male flare X female flare
- Material: Aluminum with proprietary filtration media
- Dimensions: 2" height, 2" width, 5" depth
- Weight: 0.4 lbs
- Operating Temperature Range: Suitable for typical refrigeration temperatures
- Compatibility: Replaces OEM part number 033116-01, compatible with all common refrigerants
- Installation: Flare fittings support quick, secure connections in system lines
- Construction Finish: Anodized aluminum for corrosion resistance
What is a commercial liquid line filter drier
A commercial liquid line filter drier is a critical component within refrigeration and HVAC systems, designed to remove moisture, dirt, and other contaminants from the refrigerant. Installed inline in the liquid refrigerant line, it ensures system cleanliness, prevents corrosion, and prolongs equipment lifespan. The Parker Hannifin 033116-01 filter drier is a reliable OEM solution with a compact form, suitable for various commercial refrigeration applications, including HVAC units, beverage coolers, and cold storage facilities. Its durable construction and compatibility with all common refrigerants make it an essential part of maintaining efficient and dependable cooling systems in foodservice settings, hospitals, and large-scale facilities.
Top Commercial Liquid Line Filter Driers for Refrigeration Systems
Designed for medium-volume refrigeration operations, the Parker Hannifin 033116-01 provides robust filtration and moisture removal, supporting consistent system performance in commercial foodservice environments. Built with high-quality materials and integrated into standard refrigeration lines, it ensures longevity and operational reliability. The model is ideal for HVAC technicians maintaining or installing reliable, compact, restaurant-ready cooling systems that demand efficient moisture control and contaminant filtration for long-term service.
- Operational for medium workload commercial refrigeration
- Suitable for compact commercial kitchen spaces
- Supports refrigeration maintenance and system integrity
- Designed for moderate throughput foodservice applications
- Optimal for system filtration and moisture control
Why Choose AllPoints 033116-01
The AllPoints 033116-01 filter drier stands out among competitive models due to its durable aluminum construction, proven reliability, and compatibility with a broad range of refrigerants. Its compact design and secure flare fittings streamline installation and maintenance, enhancing operational efficiency in commercial HVAC setups. Engineered for long-term performance, it reduces refrigerant leaks and system downtime, making it a preferred choice for professional refrigeration service providers seeking quality, performance, and ease of integration.
- Compact footprint: Facilitates installation in tight spaces
- Corrosion-resistant materials: Ensures reliable long-term operation
- Secure flare fittings: Simplifies connection and maintenance
- Versatile refrigerant compatibility: Supports all commonly used refrigerants